CodingBox Tài liệu

Abbreviations A–Z

Đội ngũ của chúng tôi đang thực hiện bản dịch. Bài viết này tạm thời chưa có bản tiếng Việt và đang được hiển thị bằng tiếng Anh.

Optics documentation is written in acronyms: a datasheet line reads "SFP28 SR, 850 nm VCSEL, RS-FEC, OMA −6 dBm, DDM per SFF-8472". This index expands the abbreviations you meet in datasheets, switch output and CodingBox screens, with one line of meaning and a link to the material that explains the concept. For definitions of concepts rather than expansions see the Glossary.

A–B

Abbr.ExpansionMeaning
A0h / A2htwo-wire addresses 0xA0 / 0xA2identity and diagnostics memory of SFP-class modules (Memory map)
AECActive Electrical Cablecopper cable with retimers/DSP in the plugs (Cable internals)
ACCActive Copper Cablecopper cable with linear amplifiers, no retiming
ANAuto-Negotiationspeed/FEC negotiation, IEEE 802.3 Clause 73 on DAC (FEC & AN)
AOCActive Optical Cablefibre cable with fixed transceivers at both ends
APCAngled Physical Contact8° angled connector polish, green (Connectors)
APDAvalanche Photodiodehigh-sensitivity receiver for long reach (Receivers)
ASEAmplified Spontaneous Emissionnoise generated by optical amplifiers (OSNR)
ASICApplication-Specific Integrated Circuitthe switch forwarding chip (Inside a switch)
AUIAttachment Unit Interfacechip-to-module electrical interface: XAUI, CAUI-4, 400GAUI-8…
AWGArrayed Waveguide Grating / American Wire GaugeDWDM mux technology / copper conductor gauge in DAC
BASE-R / BASE-XIEEE PCS families: 64b/66b (R) and 8b/10b (X)
BERBit Error Ratioerrored bits ÷ transmitted bits (Units)
BiDiBidirectionalone-fibre link with two wavelengths (Wavelength bands)
BOSABidirectional Optical Sub-AssemblyTOSA + ROSA + filter in one package

C–D

Abbr.ExpansionMeaning
CAUI100 Gb/s AUICAUI-10 (10 × 10G), CAUI-4 (4 × 25G)
CC_BASE / CC_EXT / CC_DMIchecksumsEEPROM checksums per SFF-8472/8636 (Checksums)
CDBCommand Data BlockCMIS command mechanism (firmware upgrade etc.) (CMIS)
CDRClock and Data Recoveryretiming circuit (CDR)
CEICommon Electrical I/OOIF electrical interface specs (CEI-28G, -56G, -112G)
CFPC Form-factor Pluggable100G/coherent module family
CMISCommon Management Interface Specificationmanagement for QSFP-DD, OSFP and others
COBChip-on-Boarddie-on-PCB packaging (COB)
CPOCo-Packaged Opticsoptics integrated with the switch ASIC
CPRI / eCPRICommon Public Radio Interfacemobile fronthaul protocols (Fronthaul)
CR / CR4 / CR8copperIEEE PMD names for DAC (25GBASE-CR, 100GBASE-CR4)
CRCCyclic Redundancy Checkframe check; CRC errors = link errors
CWDMCoarse WDM20 nm grid, 18 channels (CWDM)
DACDirect Attach Cablepassive twinax copper cable
DCMDispersion Compensation Modulefibre spool or grating compensating chromatic dispersion
DDM / DOMDigital Diagnostics Monitoring / Digital Optical Monitoringlive temperature, voltage, bias, powers (DDM basics)
DFBDistributed Feedback lasersingle-mode laser for 1310/1550 nm (Lasers)
DMLDirectly Modulated Laserlaser whose current is modulated
DPData PathCMIS lane group with its state machine
DR / DR4 / DR8500 m PMDsingle-mode parallel 500 m PMDs
DSPDigital Signal ProcessorPAM4 and coherent signal processing (DSP)
DWDMDense WDM100/50 GHz grid (DWDM)

E–G

Abbr.ExpansionMeaning
EDFAErbium-Doped Fibre AmplifierC/L-band optical amplifier
EEPROMElectrically Erasable Programmable ROMmodule memory
EMLExternally Modulated LaserDFB + electro-absorption modulator
EPON / GPON / XGS-PONEthernet / Gigabit / 10G-symmetric PONPON generations (PON standards)
ER / ER4 / ER8Extended Reach40 km PMDs
ER (optical)Extinction RatioP1/P0 of the transmitter, dB
ESDElectrostatic Dischargehandling hazard for modules
FC / GFCFibre Channel / Gigabit FCstorage network (Fibre Channel)
FECForward Error CorrectionBASE-R (Fire code), RS-FEC (528/544)
FPFabry-Pérot lasermulti-mode laser for short SMF links
FR / FR4 / FR82 km PMDsingle-mode 2 km PMDs
FTTxFibre To The xhome/building/curb access
GBICGigabit Interface Converterfirst-generation 1G module (GBIC)
GAUIe.g. 400GAUI-8AUI at 400G with 8 lanes
GBdgigabaudsymbols per second (Units)

H–L

Abbr.ExpansionMeaning
HA / HW / LA / LWHigh Alarm / High Warning / Low Alarm / Low WarningDDM thresholds (Thresholds)
HBAHost Bus AdapterFC server adapter
HDR / NDR / XDRInfiniBand generations200 / 400 / 800 Gb/s (InfiniBand speeds)
I²C / TWIInter-Integrated Circuit / Two-Wire Interfacethe management bus (Two-wire interface)
IBInfiniBandHPC/AI interconnect
IECInternational Electrotechnical Commissionconnector, fibre, laser-safety standards (Standards map)
IEEE 802.3Ethernet working groupPMD, PCS, FEC standards
INF-8077iXFP MSA documentXFP management (XFP)
ITU-TInternational Telecommunication Union, Telecom sectorfibre (G.652), grids (G.694.x), PON (G.984/G.9807), OTN (G.709)
KR / KR4backplaneIEEE backplane PMDs; KP4 = RS(544,514) FEC
LCLucent Connectorthe standard duplex connector
LOLLoss of LockCDR cannot lock
LOSLoss of Signalreceiver sees no light
LPMode / LowPwrLow Power modemodule held at ≤ 1.5 W (Power & thermal)
LPOLinear Pluggable OpticsDSP-less module relying on host equalisation
LR / LR4 / LR8Long Reach10 km PMDs
LRMLong Reach Multimode10GBASE-LRM, 220 m on OM1/OM2
LWDM / LAN-WDMLAN Wavelength Division Multiplexing800 GHz grid around 1300 nm used by LR4/ER4
LW / SW / ELWLong / Short / Extended Long WaveFibre Channel optic types

M–O

Abbr.ExpansionMeaning
MACMedia Access ControlEthernet framing layer
MDIOManagement Data I/OPHY management bus (not used by modules)
MISManagement Interface SpecificationSFP-DD management (MIS)
MMF / SMFMulti-Mode / Single-Mode Fibre50/62.5 µm core vs 9 µm
ModPrsL / MOD_ABSModule Present (active low) / Module Absentpresence pin
MPO / MTPMulti-fibre Push-On / MTP® brand12/16/24-fibre connector
MSAMulti-Source Agreementindustry agreement for a form factor (MSA overview)
MTBFMean Time Between Failuresreliability figure, hours
MZMMach-Zehnder Modulatorexternal modulator (silicon photonics, coherent)
NICNetwork Interface Cardserver adapter
NOSNetwork Operating Systemswitch software (NOS landscape)
NRZNon-Return-to-Zerotwo-level modulation
NVMe-oFNVMe over Fabricsstorage protocol (NVMe-oF)
OADM / ROADM(Reconfigurable) Optical Add-Drop MultiplexerWDM node
OIFOptical Internetworking ForumCEI, 400ZR, CMIS 5.x
OLT / ONU / ONTOptical Line / Network Terminal / UnitPON head-end and subscriber ends
OM1–OM5 / OS1–OS2Optical Multimode / Singlemode gradesISO/IEC 11801 fibre classes
OMAOptical Modulation AmplitudeP1 − P0, the modulated power
OSFPOctal SFP8-lane form factor (OSFP)
OSNROptical Signal-to-Noise RatiodB in 0.1 nm, DWDM quality figure
OTDROptical Time-Domain Reflectometerfibre fault locator
OTNOptical Transport NetworkITU-T G.709 framing
OUIOrganizationally Unique IdentifierIEEE vendor ID in EEPROM (Vendor fields)

P–R

Abbr.ExpansionMeaning
PAM44-level Pulse Amplitude Modulation2 bits per symbol
PCS / PMA / PMDPhysical Coding / Medium Attachment / Medium Dependent sublayersIEEE physical layer stack
PFC / ECNPriority Flow Control / Explicit Congestion Notificationlossless Ethernet (Lossless Ethernet)
PICPhotonic Integrated Circuitintegrated optics chip
PINp-i-n photodiodestandard receiver
PLLPhase-Locked Loopclock circuit
PN / SNPart Number / Serial Numberidentity fields (Part numbering)
PONPassive Optical Networkshared-fibre access network
PRBSPseudo-Random Binary Sequencetest pattern (PRBS31, PRBS13Q)
PSM4Parallel Single Mode 4-lane100G 500 m MSA
QSAQSFP-to-SFP Adapterrun an SFP module in a QSFP port (Port types)
QSFP / QSFP-DDQuad SFP / Double Density4- and 8-lane form factors
RDMA / RoCERemote Direct Memory Access / RDMA over Converged EthernetAI/storage transport
RINRelative Intensity Noiselaser noise figure
RMAReturn Merchandise Authorizationwarranty return
RoHSRestriction of Hazardous SubstancesEU directive, label marking
ROSA / TOSAReceiver / Transmitter Optical Sub-Assemblyoptical front end (Components)
RS / RS0 / RS1Rate Selectpins/bits selecting rate (Rate select)
RS-FECReed-Solomon FECRS(528,514) Clause 91/108, RS(544,514) KP4
Rx / TxReceive / Transmit
RX_LOSreceiver loss of signal pinhardware LOS output

S

Abbr.ExpansionMeaning
SANStorage Area NetworkFC or Ethernet storage fabric
SCSubscriber Connector2.5 mm push-pull connector
SerDesSerializer/Deserializerhigh-speed lane transceiver in ASICs
SFF / SNIASmall Form Factor committee / Storage Networking Industry Associationpublishers of SFF-8xxx
SFI / SFI+SFP+ high-speed serial interfaceelectrical interface of SFP+ (SFF-8431)
SFP / SFP+ / SFP28 / SFP56 / SFP-DDSmall Form-factor Pluggable family1 / 10 / 25 / 50 / 100 Gb/s (Form factors)
SGMIISerial Gigabit Media Independent Interface1G copper SFP electrical mode
SiPhSilicon PhotonicsCMOS-made optics
SMSRSide-Mode Suppression Ratiosingle-mode laser purity, dB
SNMPSimple Network Management Protocolmonitoring (Monitoring)
SNRSignal-to-Noise Ratio
SOASemiconductor Optical Amplifieron-chip preamplifier
SONiCSoftware for Open Networking in the Cloudopen NOS
SR / SR4 / SR8Short Reach850 nm multi-mode PMDs
SWDMShort Wavelength Division Multiplexing4 wavelengths 850–940 nm on OM5

T–Z

Abbr.ExpansionMeaning
TDECQTransmitter and Dispersion Eye Closure QuaternaryPAM4 transmitter quality, dB
TDPTransmitter Dispersion PenaltyNRZ transmitter penalty, dB
TECThermo-Electric CoolerPeltier element stabilising laser temperature
TIATrans-Impedance Amplifier / Telecommunications Industry Associationreceiver amplifier / standards body (TIA-568)
TX_DISABLE / TX_FAULTtransmitter disable / fault pinshardware control and status (SFP hardware)
UIUnit Intervalone symbol period
UPCUltra Physical Contactflat polish, blue connectors
USRUltra Short Reachvendor 850 nm PMD, ~100 m on OM3
VCSELVertical-Cavity Surface-Emitting Laser850 nm multi-mode laser
VDMVersatile Diagnostics MonitoringCMIS advanced diagnostics (VDM)
VOAVariable Optical Attenuatoradjustable attenuator
VRP / EOS / NX-OS / Junosvendor NOS namesHuawei / Arista / Cisco / Juniper
WDMWavelength Division Multiplexingmany wavelengths on one fibre
XAUI / XGMII10 Gigabit AUI / Media Independent Interface10G chip interfaces
XFP10 Gigabit Small Form-factor Pluggablelegacy 10G module (XFP)
XG-PON / XGS-PON10-Gigabit (Symmetric) PONITU-T G.987 / G.9807
XLAUI40 Gb/s AUI4 × 10G
ZR / ZR+80 km PMD; coherent 400ZR/OpenZR+ (Coherent)

In CodingBox

Most of these abbreviations appear verbatim on the Check screen — compliance codes, DDM flags, CMIS states, power classes. The glossary explains the concepts; this page decodes the letters.


Nếu bạn phát hiện thông tin chưa chính xác hoặc lỗi trong bài viết này, hãy chọn đoạn liên quan và nhấn Ctrl+Enter để .