Abbreviations A–Z
Đội ngũ của chúng tôi đang thực hiện bản dịch. Bài viết này tạm thời chưa có bản tiếng Việt và đang được hiển thị bằng tiếng Anh.
Optics documentation is written in acronyms: a datasheet line reads "SFP28 SR, 850 nm VCSEL, RS-FEC, OMA −6 dBm, DDM per SFF-8472". This index expands the abbreviations you meet in datasheets, switch output and CodingBox screens, with one line of meaning and a link to the material that explains the concept. For definitions of concepts rather than expansions see the Glossary.
A–B
| Abbr. | Expansion | Meaning |
|---|
| A0h / A2h | two-wire addresses 0xA0 / 0xA2 | identity and diagnostics memory of SFP-class modules (Memory map) |
| AEC | Active Electrical Cable | copper cable with retimers/DSP in the plugs (Cable internals) |
| ACC | Active Copper Cable | copper cable with linear amplifiers, no retiming |
| AN | Auto-Negotiation | speed/FEC negotiation, IEEE 802.3 Clause 73 on DAC (FEC & AN) |
| AOC | Active Optical Cable | fibre cable with fixed transceivers at both ends |
| APC | Angled Physical Contact | 8° angled connector polish, green (Connectors) |
| APD | Avalanche Photodiode | high-sensitivity receiver for long reach (Receivers) |
| ASE | Amplified Spontaneous Emission | noise generated by optical amplifiers (OSNR) |
| ASIC | Application-Specific Integrated Circuit | the switch forwarding chip (Inside a switch) |
| AUI | Attachment Unit Interface | chip-to-module electrical interface: XAUI, CAUI-4, 400GAUI-8… |
| AWG | Arrayed Waveguide Grating / American Wire Gauge | DWDM mux technology / copper conductor gauge in DAC |
| BASE-R / BASE-X | — | IEEE PCS families: 64b/66b (R) and 8b/10b (X) |
| BER | Bit Error Ratio | errored bits ÷ transmitted bits (Units) |
| BiDi | Bidirectional | one-fibre link with two wavelengths (Wavelength bands) |
| BOSA | Bidirectional Optical Sub-Assembly | TOSA + ROSA + filter in one package |
C–D
| Abbr. | Expansion | Meaning |
|---|
| CAUI | 100 Gb/s AUI | CAUI-10 (10 × 10G), CAUI-4 (4 × 25G) |
| CC_BASE / CC_EXT / CC_DMI | checksums | EEPROM checksums per SFF-8472/8636 (Checksums) |
| CDB | Command Data Block | CMIS command mechanism (firmware upgrade etc.) (CMIS) |
| CDR | Clock and Data Recovery | retiming circuit (CDR) |
| CEI | Common Electrical I/O | OIF electrical interface specs (CEI-28G, -56G, -112G) |
| CFP | C Form-factor Pluggable | 100G/coherent module family |
| CMIS | Common Management Interface Specification | management for QSFP-DD, OSFP and others |
| COB | Chip-on-Board | die-on-PCB packaging (COB) |
| CPO | Co-Packaged Optics | optics integrated with the switch ASIC |
| CPRI / eCPRI | Common Public Radio Interface | mobile fronthaul protocols (Fronthaul) |
| CR / CR4 / CR8 | copper | IEEE PMD names for DAC (25GBASE-CR, 100GBASE-CR4) |
| CRC | Cyclic Redundancy Check | frame check; CRC errors = link errors |
| CWDM | Coarse WDM | 20 nm grid, 18 channels (CWDM) |
| DAC | Direct Attach Cable | passive twinax copper cable |
| DCM | Dispersion Compensation Module | fibre spool or grating compensating chromatic dispersion |
| DDM / DOM | Digital Diagnostics Monitoring / Digital Optical Monitoring | live temperature, voltage, bias, powers (DDM basics) |
| DFB | Distributed Feedback laser | single-mode laser for 1310/1550 nm (Lasers) |
| DML | Directly Modulated Laser | laser whose current is modulated |
| DP | Data Path | CMIS lane group with its state machine |
| DR / DR4 / DR8 | 500 m PMD | single-mode parallel 500 m PMDs |
| DSP | Digital Signal Processor | PAM4 and coherent signal processing (DSP) |
| DWDM | Dense WDM | 100/50 GHz grid (DWDM) |
E–G
| Abbr. | Expansion | Meaning |
|---|
| EDFA | Erbium-Doped Fibre Amplifier | C/L-band optical amplifier |
| EEPROM | Electrically Erasable Programmable ROM | module memory |
| EML | Externally Modulated Laser | DFB + electro-absorption modulator |
| EPON / GPON / XGS-PON | Ethernet / Gigabit / 10G-symmetric PON | PON generations (PON standards) |
| ER / ER4 / ER8 | Extended Reach | 40 km PMDs |
| ER (optical) | Extinction Ratio | P1/P0 of the transmitter, dB |
| ESD | Electrostatic Discharge | handling hazard for modules |
| FC / GFC | Fibre Channel / Gigabit FC | storage network (Fibre Channel) |
| FEC | Forward Error Correction | BASE-R (Fire code), RS-FEC (528/544) |
| FP | Fabry-Pérot laser | multi-mode laser for short SMF links |
| FR / FR4 / FR8 | 2 km PMD | single-mode 2 km PMDs |
| FTTx | Fibre To The x | home/building/curb access |
| GBIC | Gigabit Interface Converter | first-generation 1G module (GBIC) |
| GAUI | e.g. 400GAUI-8 | AUI at 400G with 8 lanes |
| GBd | gigabaud | symbols per second (Units) |
H–L
| Abbr. | Expansion | Meaning |
|---|
| HA / HW / LA / LW | High Alarm / High Warning / Low Alarm / Low Warning | DDM thresholds (Thresholds) |
| HBA | Host Bus Adapter | FC server adapter |
| HDR / NDR / XDR | InfiniBand generations | 200 / 400 / 800 Gb/s (InfiniBand speeds) |
| I²C / TWI | Inter-Integrated Circuit / Two-Wire Interface | the management bus (Two-wire interface) |
| IB | InfiniBand | HPC/AI interconnect |
| IEC | International Electrotechnical Commission | connector, fibre, laser-safety standards (Standards map) |
| IEEE 802.3 | Ethernet working group | PMD, PCS, FEC standards |
| INF-8077i | XFP MSA document | XFP management (XFP) |
| ITU-T | International Telecommunication Union, Telecom sector | fibre (G.652), grids (G.694.x), PON (G.984/G.9807), OTN (G.709) |
| KR / KR4 | backplane | IEEE backplane PMDs; KP4 = RS(544,514) FEC |
| LC | Lucent Connector | the standard duplex connector |
| LOL | Loss of Lock | CDR cannot lock |
| LOS | Loss of Signal | receiver sees no light |
| LPMode / LowPwr | Low Power mode | module held at ≤ 1.5 W (Power & thermal) |
| LPO | Linear Pluggable Optics | DSP-less module relying on host equalisation |
| LR / LR4 / LR8 | Long Reach | 10 km PMDs |
| LRM | Long Reach Multimode | 10GBASE-LRM, 220 m on OM1/OM2 |
| LWDM / LAN-WDM | LAN Wavelength Division Multiplexing | 800 GHz grid around 1300 nm used by LR4/ER4 |
| LW / SW / ELW | Long / Short / Extended Long Wave | Fibre Channel optic types |
M–O
| Abbr. | Expansion | Meaning |
|---|
| MAC | Media Access Control | Ethernet framing layer |
| MDIO | Management Data I/O | PHY management bus (not used by modules) |
| MIS | Management Interface Specification | SFP-DD management (MIS) |
| MMF / SMF | Multi-Mode / Single-Mode Fibre | 50/62.5 µm core vs 9 µm |
| ModPrsL / MOD_ABS | Module Present (active low) / Module Absent | presence pin |
| MPO / MTP | Multi-fibre Push-On / MTP® brand | 12/16/24-fibre connector |
| MSA | Multi-Source Agreement | industry agreement for a form factor (MSA overview) |
| MTBF | Mean Time Between Failures | reliability figure, hours |
| MZM | Mach-Zehnder Modulator | external modulator (silicon photonics, coherent) |
| NIC | Network Interface Card | server adapter |
| NOS | Network Operating System | switch software (NOS landscape) |
| NRZ | Non-Return-to-Zero | two-level modulation |
| NVMe-oF | NVMe over Fabrics | storage protocol (NVMe-oF) |
| OADM / ROADM | (Reconfigurable) Optical Add-Drop Multiplexer | WDM node |
| OIF | Optical Internetworking Forum | CEI, 400ZR, CMIS 5.x |
| OLT / ONU / ONT | Optical Line / Network Terminal / Unit | PON head-end and subscriber ends |
| OM1–OM5 / OS1–OS2 | Optical Multimode / Singlemode grades | ISO/IEC 11801 fibre classes |
| OMA | Optical Modulation Amplitude | P1 − P0, the modulated power |
| OSFP | Octal SFP | 8-lane form factor (OSFP) |
| OSNR | Optical Signal-to-Noise Ratio | dB in 0.1 nm, DWDM quality figure |
| OTDR | Optical Time-Domain Reflectometer | fibre fault locator |
| OTN | Optical Transport Network | ITU-T G.709 framing |
| OUI | Organizationally Unique Identifier | IEEE vendor ID in EEPROM (Vendor fields) |
P–R
| Abbr. | Expansion | Meaning |
|---|
| PAM4 | 4-level Pulse Amplitude Modulation | 2 bits per symbol |
| PCS / PMA / PMD | Physical Coding / Medium Attachment / Medium Dependent sublayers | IEEE physical layer stack |
| PFC / ECN | Priority Flow Control / Explicit Congestion Notification | lossless Ethernet (Lossless Ethernet) |
| PIC | Photonic Integrated Circuit | integrated optics chip |
| PIN | p-i-n photodiode | standard receiver |
| PLL | Phase-Locked Loop | clock circuit |
| PN / SN | Part Number / Serial Number | identity fields (Part numbering) |
| PON | Passive Optical Network | shared-fibre access network |
| PRBS | Pseudo-Random Binary Sequence | test pattern (PRBS31, PRBS13Q) |
| PSM4 | Parallel Single Mode 4-lane | 100G 500 m MSA |
| QSA | QSFP-to-SFP Adapter | run an SFP module in a QSFP port (Port types) |
| QSFP / QSFP-DD | Quad SFP / Double Density | 4- and 8-lane form factors |
| RDMA / RoCE | Remote Direct Memory Access / RDMA over Converged Ethernet | AI/storage transport |
| RIN | Relative Intensity Noise | laser noise figure |
| RMA | Return Merchandise Authorization | warranty return |
| RoHS | Restriction of Hazardous Substances | EU directive, label marking |
| ROSA / TOSA | Receiver / Transmitter Optical Sub-Assembly | optical front end (Components) |
| RS / RS0 / RS1 | Rate Select | pins/bits selecting rate (Rate select) |
| RS-FEC | Reed-Solomon FEC | RS(528,514) Clause 91/108, RS(544,514) KP4 |
| Rx / Tx | Receive / Transmit | — |
| RX_LOS | receiver loss of signal pin | hardware LOS output |
S
| Abbr. | Expansion | Meaning |
|---|
| SAN | Storage Area Network | FC or Ethernet storage fabric |
| SC | Subscriber Connector | 2.5 mm push-pull connector |
| SerDes | Serializer/Deserializer | high-speed lane transceiver in ASICs |
| SFF / SNIA | Small Form Factor committee / Storage Networking Industry Association | publishers of SFF-8xxx |
| SFI / SFI+ | SFP+ high-speed serial interface | electrical interface of SFP+ (SFF-8431) |
| SFP / SFP+ / SFP28 / SFP56 / SFP-DD | Small Form-factor Pluggable family | 1 / 10 / 25 / 50 / 100 Gb/s (Form factors) |
| SGMII | Serial Gigabit Media Independent Interface | 1G copper SFP electrical mode |
| SiPh | Silicon Photonics | CMOS-made optics |
| SMSR | Side-Mode Suppression Ratio | single-mode laser purity, dB |
| SNMP | Simple Network Management Protocol | monitoring (Monitoring) |
| SNR | Signal-to-Noise Ratio | — |
| SOA | Semiconductor Optical Amplifier | on-chip preamplifier |
| SONiC | Software for Open Networking in the Cloud | open NOS |
| SR / SR4 / SR8 | Short Reach | 850 nm multi-mode PMDs |
| SWDM | Short Wavelength Division Multiplexing | 4 wavelengths 850–940 nm on OM5 |
T–Z
| Abbr. | Expansion | Meaning |
|---|
| TDECQ | Transmitter and Dispersion Eye Closure Quaternary | PAM4 transmitter quality, dB |
| TDP | Transmitter Dispersion Penalty | NRZ transmitter penalty, dB |
| TEC | Thermo-Electric Cooler | Peltier element stabilising laser temperature |
| TIA | Trans-Impedance Amplifier / Telecommunications Industry Association | receiver amplifier / standards body (TIA-568) |
| TX_DISABLE / TX_FAULT | transmitter disable / fault pins | hardware control and status (SFP hardware) |
| UI | Unit Interval | one symbol period |
| UPC | Ultra Physical Contact | flat polish, blue connectors |
| USR | Ultra Short Reach | vendor 850 nm PMD, ~100 m on OM3 |
| VCSEL | Vertical-Cavity Surface-Emitting Laser | 850 nm multi-mode laser |
| VDM | Versatile Diagnostics Monitoring | CMIS advanced diagnostics (VDM) |
| VOA | Variable Optical Attenuator | adjustable attenuator |
| VRP / EOS / NX-OS / Junos | vendor NOS names | Huawei / Arista / Cisco / Juniper |
| WDM | Wavelength Division Multiplexing | many wavelengths on one fibre |
| XAUI / XGMII | 10 Gigabit AUI / Media Independent Interface | 10G chip interfaces |
| XFP | 10 Gigabit Small Form-factor Pluggable | legacy 10G module (XFP) |
| XG-PON / XGS-PON | 10-Gigabit (Symmetric) PON | ITU-T G.987 / G.9807 |
| XLAUI | 40 Gb/s AUI | 4 × 10G |
| ZR / ZR+ | — | 80 km PMD; coherent 400ZR/OpenZR+ (Coherent) |
In CodingBox
Most of these abbreviations appear verbatim on the Check screen — compliance codes, DDM flags, CMIS states, power classes. The glossary explains the concepts; this page decodes the letters.