CodingBox Tài liệu

SFP

Đội ngũ của chúng tôi đang thực hiện bản dịch. Bài viết này tạm thời chưa có bản tiếng Việt và đang được hiển thị bằng tiếng Anh.

The Small Form-factor Pluggable (SFP) replaced the GBIC and became the most common optical module ever made. Its footprint is still used, unchanged, by SFP+, SFP28 and SFP56 — which is why a modern 50G port is physically the same size as a 1G port from two decades ago.

Key facts

Lanes × rate1 × up to ~4.25 Gb/s
Total1G class (also 2G/4G FC, OC-3/12/48)
ConnectorLC duplex (also simplex BiDi, RJ45 copper)
Supply3.3 V
Applications1000BASE-SX/LX/EX/ZX/BX, 1/2/4GFC, SONET/SDH, CWDM/DWDM SFP

Specifications

  • INF-8074SFP Transceiver 1.0: the original SFP MSA (mechanical, electrical).
  • SFF-8432SFP+ Module and Cage: the improved mechanical definition also used for SFP.
  • SFF-8472Management Interface: identification, DDM and thresholds.
  • SFF-8079SFP Rate and Application Selection; SFF-8089SFP Rate and Application Codes.
  • SFF-8075PCI Card Version of SFP Cage.

Management interface

SFP uses the two-address model of SFF-8472:

  • A0h — serial ID: vendor, part number, serial, transceiver codes, wavelength, distances, and the CC_BASE / CC_EXT checksums.
  • A2h — digital diagnostics: live monitors, alarm/warning thresholds, flags, and — on protected modules — the password area at offset 0x7B.

Not every 1G SFP implements A2h diagnostics; a capability bit in A0h says whether DDM is present.

Compatibility notes

  • Fits SFP+, SFP28 and SFP56 cages (rate permitting).
  • Coloured CWDM SFPs and DWDM SFPs use the same memory layout with the wavelength field set — see CWDM.

In CodingBox

Fully supported: read, decode, edit and write per SFF-8472 with automatic CC_BASE/CC_EXT recalculation in the EEPROM editor. Protected modules are handled through Protected memory & passwords.


Nếu bạn phát hiện thông tin chưa chính xác hoặc lỗi trong bài viết này, hãy chọn đoạn liên quan và nhấn Ctrl+Enter để .