INF-8077i XFP register map
Đội ngũ của chúng tôi đang thực hiện bản dịch. Bài viết này tạm thời chưa có bản tiếng Việt và đang được hiển thị bằng tiếng Anh.
An XFP module answers at one two-wire address (A0h) with a lower memory of 128 bytes — thresholds, flags, monitors and control — and upper tables selected by byte 127, of which table 01h is the serial ID. The layout predates SFF-8636 and was its model: the QSFP identity block copies XFP's byte positions almost exactly. This page lists the lower memory and table 01h byte by byte and bit by bit, compiled against INF-8077i Rev 4.5. Narrative: INF-8077i — XFP management.
Legend: rsvd = reserved · vendor = vendor specific · 16-bit values are MSB first · flags are latched, cleared on read.
Lower memory — thresholds, bytes 0–57
| Byte | Field | Notes |
|---|
| 0 | Identifier | 06h = XFP |
| 1 | Signal conditioner control | 7 Tx CDR bypass? — bits control internal Tx/Rx CDR and loopbacks per Table 39: 7 Tx CDR off · 6 Tx amplitude/EQ control · 5–4 rsvd · 3 Rx CDR off · 2 line-side loopback · 1 XFI loopback · 0 rsvd (implementation advertised in table 01h byte 164) |
| 2–3 / 4–5 / 6–7 / 8–9 | Temperature high alarm / low alarm / high warning / low warning | signed 16-bit, 1/256 °C |
| 10–17 | rsvd | (thresholds for a second temperature in some drafts) |
| 18–19 / 20–21 / 22–23 / 24–25 | Tx bias HA / LA / HW / LW | unsigned 16-bit, 2 µA |
| 26–27 / 28–29 / 30–31 / 32–33 | Tx power HA / LA / HW / LW | unsigned 16-bit, 0.1 µW |
| 34–35 / 36–37 / 38–39 / 40–41 | Rx power HA / LA / HW / LW | unsigned 16-bit, 0.1 µW |
| 42–43 / 44–45 / 46–47 / 48–49 | AUX1 HA / LA / HW / LW | format per AUX1 type (table 01h byte 222) |
| 50–57 | AUX2 HA / LA / HW / LW | as AUX2 type |
Lower memory — vendor, BER and wavelength control, bytes 58–79
| Byte | Field | Contents |
|---|
| 58–69 | vendor | — |
| 70 | BER reporting | for modules with FEC: BER exponent/mantissa reporting control |
| 71 | Wavelength control — target MSB | tunable XFP: 71–72 wavelength set in 0.05 nm units |
| 72 | Wavelength control — target LSB | — |
| 73–74 | Wavelength error / status | reported wavelength offset in 0.005 nm units |
| 75 | Wavelength control flags | tuning in progress, unlocked, out of range |
| 76–79 | FEC control | enable/disable FEC, FEC status (10G FEC XFPs, ITU G.709 wrapped) |
Lower memory — flags, bytes 80–95
| Byte | Field | Bits |
|---|
| 80 | Alarm flags 1 (latched) | 7 temp high alarm · 6 temp low alarm · 5 rsvd · 4 rsvd · 3 Tx bias high alarm · 2 Tx bias low alarm · 1 Tx power high alarm · 0 Tx power low alarm |
| 81 | Alarm flags 2 (latched) | 7 Rx power high alarm · 6 Rx power low alarm · 5 AUX1 high alarm · 4 AUX1 low alarm · 3 AUX2 high alarm · 2 AUX2 low alarm · 1–0 rsvd |
| 82 | Warning flags 1 (latched) | same layout as byte 80 for warnings |
| 83 | Warning flags 2 (latched) | same layout as byte 81 for warnings |
| 84 | Status flags 1 (latched) | 7 Tx_NR (not ready) · 6 Tx_Fault · 5 Tx CDR not locked · 4 Rx_NR · 3 Rx CDR not locked · 2 RX_LOS · 1 module not ready (Mod_NR) · 0 reset complete |
| 85 | Status flags 2 (latched) | 7 APD supply fault · 6 TEC fault · 5 wavelength unlocked · 4–3 rsvd · 2 VCC5 fault? · 1 VCC3 fault · 0 VCC2 fault (supply-fault bits per implementation) |
| 86–87 | rsvd | — |
| 88 | Alarm masks 1 | mask bits for byte 80 |
| 89 | Alarm masks 2 | for byte 81 |
| 90 | Warning masks 1 | for byte 82 |
| 91 | Warning masks 2 | for byte 83 |
| 92 | Status masks 1 | for byte 84 |
| 93 | Status masks 2 | for byte 85 |
| 94–95 | rsvd | — |
A set flag asserts the Interrupt pin unless masked; the host reads the flag bytes to clear them.
Lower memory — A/D readouts, bytes 96–109
| Bytes | Monitor | Format |
|---|
| 96–97 | Temperature | signed 16-bit, 1/256 °C |
| 98–99 | rsvd | — |
| 100–101 | Tx bias | 2 µA |
| 102–103 | Tx power | 0.1 µW |
| 104–105 | Rx power | 0.1 µW |
| 106–107 | AUX1 | per type in table 01h byte 222 |
| 108–109 | AUX2 | per type |
Lower memory — control and status, bytes 110–127
| Byte | Field | Bits |
|---|
| 110 | General control/status | 7 TX_DIS pin state · 6 soft TX_DIS (R/W) · 5 MOD_NR state · 4 P_Down state (pin) · 3 soft P_Down (R/W) · 2 Interrupt state · 1 RX_LOS state · 0 data not ready |
| 111 | General status 2 | 7 Tx_NR state · 6 Tx_Fault state · 5 Tx CDR not locked · 4 Rx_NR state · 3 Rx CDR not locked · 2 rsvd · 1 VPS (variable power supply) state · 0 rsvd (unlatched mirrors of byte 84) |
| 112–117 | vendor / rsvd | — |
| 118 | vendor | — |
| 119–122 | vendor | often password change area |
| 123–126 | vendor | often password entry area (same offsets as QSFP) — Write-protection types |
| 127 | Table select | 01h serial ID (default) · 02h–7Fh rsvd · 80h–FFh vendor |
Table 01h — serial ID, bytes 128–191 (covered by CC_BASE)
| Byte | Field | Contents |
|---|
| 128 | Identifier | 06h XFP |
| 129 | Extended identifier | 7–6 rsvd · 5–4 power level: 00 ≤ 1.5 W · 01 ≤ 2.5 W · 10 ≤ 3.5 W · 11 > 3.5 W · 3 CDR (0 = XFI with CDR, 1 = no CDR) · 2 CLEI code present in table 01h? (bit 2 = CLEI in table 02h) · 1 Tx reference clock input required · 0 rsvd |
| 130 | Connector | SFF-8024 Table 4-3 (07h LC · 01h SC · 21h copper pigtail · 22h RJ45) |
| 131 | 10G Ethernet compliance | 7 10GBASE-SR · 6 10GBASE-LR · 5 10GBASE-ER · 4 10GBASE-LRM · 3 10GBASE-SW · 2 10GBASE-LW · 1 10GBASE-EW · 0 rsvd |
| 132 | 10G Fibre Channel compliance | 7 1200-MX-SN-I · 6 1200-SM-LL-L · 5 extended reach 1550 nm · 4 intermediate reach 1300 nm FP · 3–0 rsvd |
| 133 | 10G copper links | 7–0 rsvd (defined for future copper XFP) |
| 134 | Lower-speed links | 7 1000BASE-SX / 1×FC MMF · 6 1000BASE-LX / 1×FC SMF · 5 2×FC MMF · 4 2×FC SMF · 3 OC-48 SR · 2 OC-48 IR · 1 OC-48 LR · 0 rsvd |
| 135 | SONET/SDH interconnect | 7 I-64.1r · 6 I-64.1 · 5 I-64.2r · 4 I-64.2 · 3 I-64.3 · 2 I-64.5 · 1–0 rsvd |
| 136 | SONET/SDH short haul | 7 S-64.1 · 6 S-64.2a · 5 S-64.2b · 4 S-64.3a · 3 S-64.3b · 2 S-64.5a · 1 S-64.5b · 0 rsvd |
| 137 | SONET/SDH long haul | 7 L-64.1 · 6 L-64.2a · 5 L-64.2b · 4 L-64.2c · 3 L-64.3 · 2 G.959.1 P1L1-2D2 · 1–0 rsvd |
| 138 | SONET/SDH very long haul | 7 V-64.2a · 6 V-64.2b · 5 V-64.3 · 4–0 rsvd |
| 139 | Encoding | 7 64B/66B · 6 8B/10B · 5 SONET scrambled · 4 NRZ · 3 RZ · 2–0 rsvd (bit field, not an SFF-8024 value) |
| 140 | Bit rate minimum | units of 100 Mb/s (e.g. 5Fh = 9.5 Gb/s) |
| 141 | Bit rate maximum | units of 100 Mb/s (e.g. 6Fh = 11.1 Gb/s) — the pair defines the supported rate window |
| 142 | Length SMF | km |
| 143 | Length E-50 µm (OM3) | units of 2 m |
| 144 | Length 50 µm | units of 1 m |
| 145 | Length 62.5 µm | units of 1 m |
| 146 | Length copper | units of 1 m |
| 147 | Device technology | 7–4 transmitter: 0h 850 nm VCSEL · 1h 1310 nm VCSEL · 2h 1550 nm VCSEL · 3h 1310 nm FP · 4h 1310 nm DFB · 5h 1550 nm DFB · 6h 1310 nm EML · 7h 1550 nm EML · 8h copper · 9h–Fh rsvd · 3 wavelength control (active) · 2 cooled transmitter · 1 detector (1 = APD, 0 = PIN) · 0 tunable |
| 148–163 | Vendor name | 16 ASCII |
| 164 | CDR support | 7 9.95 Gb/s · 6 10.3 Gb/s · 5 10.5 Gb/s · 4 10.7 Gb/s · 3 11.1 Gb/s · 2 rsvd · 1 line-side loopback supported · 0 XFI loopback supported |
| 165–167 | Vendor OUI | — |
| 168–183 | Vendor PN | 16 ASCII |
| 184–185 | Vendor rev | 2 ASCII |
| 186–187 | Wavelength | units of 0.05 nm (1310.00 nm = 26 200 = 6658h) |
| 188–189 | Wavelength tolerance | units of 0.005 nm |
| 190 | Max case temperature | °C |
| 191 | CC_BASE | (Σ bytes 128–190) mod 256 |
Table 01h — extended ID, bytes 192–255
| Byte | Field | Contents |
|---|
| 192 | Max power dissipation | units of 20 mW (e.g. 7Dh = 2.5 W) |
| 193 | Total power in power-down | units of 20 mW |
| 194 | Max current | 7–4 on +5 V in 50 mA units · 3–0 on +3.3 V in 100 mA units |
| 195 | Max current | 7–4 on +1.8 V in 100 mA units · 3–0 on −5.2 V in 50 mA units |
| 196–211 | Vendor SN | 16 ASCII |
| 212–219 | Date code | YYMMDD + 2 lot |
| 220 | Diagnostic monitoring type | 7–5 rsvd · 4 Rx power measurement: 1 = average, 0 = OMA · 3 BER reporting supported · 2–0 rsvd |
| 221 | Enhanced options | 7 VPS supported (variable power supply) · 6 soft TX_DISABLE implemented · 5 soft P_Down implemented · 4 VPS LV regulator mode · 3 VPS bypassed regulator mode · 2 active FEC control functions · 1 wavelength tunability implemented · 0 CMU (clock multiplier unit) supported |
| 222 | AUX monitoring | 7–4 AUX1 type · 3–0 AUX2 type: 0 not implemented · 1 APD bias voltage (10 mV) · 2 rsvd · 3 TEC current (0.1 mA, signed) · 4 laser temperature (1/256 °C) · 5 laser wavelength (0.05 nm? — per spec: wavelength offset) · 6 +5 V supply (100 µV) · 7 +3.3 V supply · 8 +1.8 V supply · 9 −5.2 V supply · Ah +5 V current (100 µA) · Bh rsvd · Ch +3.3 V current · Dh +1.8 V current · Eh −5.2 V current · Fh rsvd |
| 223 | CC_EXT | (Σ bytes 192–222) mod 256 |
| 224–255 | Vendor specific | not checksummed |
Tables 02h–FFh
| Table | Contents |
|---|
| 02h | user EEPROM / CLEI code (when advertised) |
| 03h–7Fh | rsvd |
| 80h–FFh | vendor specific (often passwords, calibration backups) |
What the QSFP inherited
Compare with the SFF-8636 upper page 00h map: bytes 128–130, 140–147 (lengths and technology nibble), 148–191 (vendor block, wavelength, CC_BASE), 196–223 (SN, date, CC_EXT) sit at the same offsets. The differences are the compliance bytes (131–138 redefined for 40/100G Ethernet), byte 139 (encoding as a value rather than a bit field) and 192–195 (power/current replaced by extended compliance and options). A tool that knows one map reads the other with a small translation table.