Digital Diagnostic Monitoring (DDM), also called DOM, lets a transceiver report its own operating condition in real time. CodingBox reads these values on the Check transceiver screen.
The four core parameters
- Temperature — the module's internal temperature, in °C.
- Supply voltage — the 3.3 V rail as measured inside the module.
- Laser bias current — the drive current of the transmit laser, in mA.
- TX / RX optical power — transmitted and received light power, in dBm.
Warning and alarm thresholds
Each parameter carries factory-set thresholds. Values are classified against them:
| Zone | Condition |
|---|---|
| Normal | between low and high warning |
| Warning | past a warning threshold |
| Alarm | past an alarm threshold |
Reading RX power
Received optical power is the most useful field for diagnosing a link:
RX power = -3.2 dBm → healthy
RX power = -18 dBm → near receiver sensitivity, expect errors
A low RX power usually points to a dirty connector, a bent fibre or too much distance — not necessarily a faulty module.
Going deeper
- DDM parameters & units — raw encoding and conversion to °C, V, mA, dBm.
- Thresholds, alarms & flags — where limits live and what the host acts on.
- Internal & external calibration — why some hosts show absurd values.
- Per-lane diagnostics: QSFP & CMIS — multi-lane monitors and VDM.
- Monitoring DDM in production — SNMP, link passports, trending.
Further reading
- Typical values by module type — what Tx, Rx, bias and temperature should look like for SX/LX/SR/LR/ZR, 100G, 400G, PON, AOC.
- Accuracy and limits — ±3 dB, average vs OMA, floors, where DDM is absent or fake.
- Rx power and the link budget — measured loss, margin, both directions, overload, penalties.
- Tx bias and laser ageing — the monitor that predicts failure.
- Temperature and voltage — what they change and what they reveal.
- VDM and FEC metrics — pre-FEC BER, eSNR and host FEC counters on PAM4 links.
- Reading DDM with tools — CLI, ethtool, SNMP OIDs, OpenConfig paths, decoding a raw dump.