CodingBox دستاویزات

DDM کی بنیادی باتیں

ہماری ٹیم ترجمے پر کام کر رہی ہے۔ یہ مضمون عارضی طور پر اردو میں دستیاب نہیں ہے، اس لیے اسے انگریزی میں دکھایا جا رہا ہے۔

Digital Diagnostic Monitoring (DDM), also called DOM, lets a transceiver report its own operating condition in real time. CodingBox reads these values on the Check transceiver screen.

The four core parameters

  • Temperaturethe module's internal temperature, in °C.
  • Supply voltagethe 3.3 V rail as measured inside the module.
  • Laser bias currentthe drive current of the transmit laser, in mA.
  • TX / RX optical powertransmitted and received light power, in dBm.

Warning and alarm thresholds

Each parameter carries factory-set thresholds. Values are classified against them:

ZoneCondition
Normalbetween low and high warning
Warningpast a warning threshold
Alarmpast an alarm threshold

Reading RX power

Received optical power is the most useful field for diagnosing a link:

RX power = -3.2 dBm   → healthy
RX power = -18 dBm    → near receiver sensitivity, expect errors

A low RX power usually points to a dirty connector, a bent fibre or too much distance — not necessarily a faulty module.

Going deeper

Further reading


اگر آپ کو اس مضمون میں کوئی غیر درست بات یا غلطی نظر آئے تو متعلقہ حصہ منتخب کریں اور Ctrl+Enter دبا کر ۔