Turn OTDR round-trip time into distance with the fibre group index, correct a distance measured with the wrong index, estimate the OTDR range and work out the propagation delay of a link.

Fibre
Used by every calculation on this page.
OTDR: round-trip time and distance
Latency of a fibre link
One way
—µs
Round trip
—ms
OTDR pulse length
Pulse length in the fibre, about the event dead zone
—m
Index correction
True distance
—km
Correction
—m
OTDR range
Usable range
—km

Formulas

QuantityFormulaExample
Distance from the OTDR round-trip timed = c · t / (2 · n)100 µs at n = 1.468 → 10.21 km
One-way latencyt = L · n / c100 km → 490 µs; round trip 0.98 ms
Pulse length in the fibrec · τ / (2 · n)100 ns → 10.2 m, the floor of the event dead zone
Distance with a corrected indexd_true = d_shown · n_set / n_truean index error of 0.0015 shifts distances by 0.1 %
Usable OTDR range(dynamic range − 6 dB − event losses) / attenuation40 dB, 3 dB of events, 0.2 dB/km → 155 km

c = 299 792.458 km/s. Light in fibre travels at about c / 1.468 ≈ 204 000 km/s — 4.9 µs per kilometre one way.

Group index

FibreGroup index
G.652.D single-mode, 1310 nm1.4675
G.652.D single-mode, 1550 nm1.4680
OM3/OM4 multimode, 850 nm1.482
OM3/OM4 multimode, 1300 nm1.477

Take the value from the fibre's data sheet when you have it: an OTDR set to the wrong index is wrong about every distance by the same percentage. The route to a fault is also shorter than the fibre: loose-tube cable holds 0.1–0.5 % more fibre than its length, and closures store slack.

More in the documentation: Reading an OTDR trace, Formulas and worked calculations, Fibre characterization.